Hotline: +49-7152-6064-0
BISCHOFF CHROMATOGRAPHY
  • HOME
  • HPLC INSTRUMENTS & SYSTEMS
    • HPLC / LC PUMPS >
      • PUMP 2250 (DISCONTINUED)
      • PUMP 3350
    • DETECTORS >
      • UV/VIS Multi-Wavelength Detector
      • BioQuant
      • EVAPORATIVE LIGHT SCATTERING DETECTOR
    • AUTOSAMPLER
    • COLUMN OVEN COLUMN THERMOSTAT
    • SOLVENT SELECTOR
    • FRACTION COLLECTOR
    • SOFTWARE >
      • McDAcq Control
    • DEGASSER
  • HPLC COLUMNS
    • HPLC Silica (Si) COLUMNS >
      • ProntoSIL Si
      • Kromasil Si
      • LiChrospher Si
      • Nucleosil Si
      • LiChrosorb Si
      • Partisil Silica
      • Zorbax Silica
      • Micra NPS Silica
    • HPLC C30 COLUMNS >
      • PronotSil C30
      • Micra NPS TAS (C30)
    • HPLC C18 COLUMNS >
      • ProntoSIL C18 ace-EPS
      • ProntoPEARL sub2 TPP C18 ace-EPS
      • ProntoSIL C18 H
      • ProntoSIL C18 SH
      • ProntoSIL C18 AQ
      • ProntoSIL C18 AQ PLUS
      • ProntoSIL EuroBOND C18
      • ProntoSIL HyperSorb ODS
      • ProntoSIL Spheribond ODS 1
      • ProntoSIL Spheribond ODS 2
      • Eurosil Bioselect 300 C18
      • Eurospher 100 C18
      • Kromasil C18
      • LiChrospher RP 18 und RP 18 endcapped
      • Nucleosil C18
      • Nucleosil C18 AB
      • LiChrosorb RP 18
      • Hipak ODS AB
      • Partisil ODS
      • PolyEncab C18
      • Techsphere ODS
      • Zorbax ODS
      • Sphere-Image 80 ODS1 / ODS 2
      • ProntoPEARL sub2 NPP C18
      • Micra NPS ODS
    • HPLC C8 COLUMNS >
      • ProntoSIL C8 ace-EPS
      • ProntoPEARL sub2 TPP C8 ace-EPS
      • ProntoSIL C8 SH
      • Euospher 100 C8
      • Kromasil C8
      • LiChrospher RP8 und RP8 endcapped
      • Nucleosil C8
      • LiChrosorb RP8
      • Hipak C8 AB
      • Partisil C8
      • Techsphere Octyl
      • Zorbax C8
      • LiChrospher 60 RP select B
      • LiChrosorb RP select B
      • Sphere-Image 80 C8
    • HPLC C4 COLUMNS >
      • ProntoSIL C4
      • Eurospher 100 C4
      • Kromasil C4
      • PolyEncap C4
      • Eurosil Bioselect 300 C4
    • HPLC C1 COLUMNS >
      • ProntoSIL C1
      • Eurospher 100 C1
      • LiChrosorb RP2
      • Zorbax TMS (C1)
    • HPLC C6H5 (PHENYL) COLUMNS >
      • ProntoSIL Phenyl
      • Kromasil Phenyl
      • Nucleosil Phenyl
      • Zorbax Phenyl
    • HPLC CN (Cyano) COLUMNS >
      • ProntoSIL CN
      • Eurospher 100 CN
      • Kromasil CN
      • LiChrospher CN
      • Nucleosil CN
      • LiChrosorb CN
      • Zorbax CN
      • Sphere-Image 80 CN
    • HPLC NH2 (AMINO) COLUMNS >
      • ProntoSIL Amino
      • ProntoSIL Amino E
      • PronotSIL Amino H
      • ProntoPEARL sub2 TPP APS
      • Eurospher 100 NH²
      • Kromasil NH²
      • LiChrospher NH²
      • Nucleosil NH²
      • LiChrosorb NH²
      • TechSphere Amino
      • Zorbax HN²
      • Sphere-Image 80 NH²
      • Partisil PAC (Amino)
    • HPLC DIOL COLUMNS >
      • ProntoSIL DIOL
      • Eurospher 100 DIOL
      • Kromasil DIOL
      • LiChrospher DIOL
      • Nucleosil DIOL
      • LiChrosorb DIOL
    • HPLC CHIRAL COLUMNS >
      • Chromasil Chiral
      • Eurocel 01
    • HPLC Enviro COLUMNS >
      • ProntoSIL Enviro-PTL
      • ProntoSIL Enviro-PHE
      • ProntoSIL Enviro-PES
      • ProntoSIL Enviro-PAH
    • HPLC NO2 COLUMNS >
      • Nucleosil NO²
    • HPLC IEC COLUMNS >
      • Nucleosil SB
      • Partisil SAX
      • Zorbax SAX
      • Sphere-Image 80 SAX
      • Nucleosil SA
      • Partisil SCX
      • Zorbax SCX
      • Sphere-Image 80 SCX
      • PolyEncap WCX
      • IonEx CAT-S und CAT-125
    • HPLC Polymer COLUMNS >
      • PRP-1
    • HPLC IEC (P) COLUMNS >
      • PRP-X100
      • PRP-X110 und PRP-X110S
      • RCX-10
      • RCX-30
      • Eurokat
      • CarbEx II
      • PRP-X200
      • HC-40
      • HC-75
      • PRP-X300
    • Selectivity Kits
    • HARDWARE / empty Columns
    • ORDER INFORMATION COLUMNS
    • How to choose the right COLUMN?
    • Analytical Column Hardware Dimensions
    • UHC Hardware Dimensions
    • Preparative Hardware Dimensions
  • HPLC PHASES / BULK
    • HPLC Si PHASES >
      • ProntoSIL Si
      • Eurospher 100 Si
      • LiChrospher Si
      • Nucleosil Si
      • LiChrosorb Si
      • Partisil Silica
      • Zorbax Silica
      • Micra NPS Silica
    • HPLC C30 PHASES >
      • PronotSil C30
      • Micra NPS TAS (C30)
    • HPLC C18 PHASES >
      • ProntoSIL C18 ace-EPS
      • ProntoPEARL sub2 TPP C18 ace-EPS
      • ProntoSIL C18 H
      • ProntoSIL C18 SH
      • ProntoSIL C18 AQ
      • ProntoSIL C18 AQ PLUS
      • ProntoSIL EuroBOND C18
      • ProntoSIL HyperSorb ODS
      • ProntoSIL Spheribond ODS 1
      • ProntoSIL Spheribond ODS 2
      • Eurosil Bioselect 300 C18
      • Eurospher 100 C18
      • Kromasil C18
      • Nucleosil C18
      • LiChrospher RP 18 und RP 18 endcapped
      • Nucleosil C18 AB
      • LiChrosorb RP 18
      • Hipak ODS AB
      • Partisil ODS
      • PolyEncab C18
      • Techsphere ODS
      • Zorbax ODS
      • Sphere-Image 80 ODS1 / ODS 2
      • ProntoPEARL sub2 NPP C18
      • Micra NPS ODS
    • HPLC C8 PHASES >
      • ProntoSIL C8 ace-EPS
      • ProntoPEARL sub2 TPP C8 ace-EPS
      • ProntoSIL C8 SH
      • Eurospher 100 C8
      • Kromasil C8
      • LiChrospher RP8 und RP8 endcapped
      • Nucleosil C8
      • LiChrosorb RP8
      • Hipak C8 AB
      • Partisil C8
      • Techsphere Octyl
      • Zorbax C8
      • LiChrospher 60 RP select B
      • LiChrosorb RP select B
      • Sphere-Image 80 C8
    • HPLC C4 PHASES >
      • ProntoSIL C4
      • Eurospher 100 C4
      • Kromasil C4
      • PolyEncap C4
      • Eurosil Bioselect 300 C4
    • HPLC C1 PHASES >
      • ProntoSIL C1
      • Eurospher 100 C1
      • LiChrosorb RP2
      • Zorbax TMS (C1)
    • HPLC C6H5 (PHENYL) PHASES >
      • ProntoSIL Phenyl
      • Kromasil Phenyl
      • Nucleosil Phenyl
      • Zorbax Phenyl
    • HPLC CN (Cyano) PHASES >
      • ProntoSIL CN
      • Eurospher 100 CN
      • Kromasil CN
      • LiChrospher CN
      • Nucleosil CN
      • LiChrosorb CN
      • Zorbax CN
      • ProntoSIL Amino E
      • Sphere-Image 80 CN
    • HPLC NH2 (AMINO) PHASES >
      • ProntoSIL Amino
      • PronotSIL Amino H
      • ProntoPEARL sub2 TPP APS
      • Eurospher 100 NH²
      • Kromasil NH²
      • LiChrospher NH²
      • Nucleosil NH²
      • LiChrosorb NH²
      • TechSphere Amino
      • Zorbax HN²
      • Sphere-Image 80 NH²
      • Partisil PAC (Amino)
    • HPLC DIOL PHASES >
      • ProntoSIL DIOL
      • Nucleosil DIOL
      • Eurospher 100 DIOL
      • Kromasil DIOL
      • LiChrospher DIOL
      • LiChrosorb DIOL
    • HPLC CHIRAL PHASES >
      • Kromasil Chiral
      • Eurocel 01
    • HPLC Enviro PHASES >
      • ProntoSIL Enviro-PTL
      • ProntoSIL Enviro-PHE
      • ProntoSIL Enviro-PES
      • ProntoSIL Enviro-PAH
    • HPLC NO2 (Nitro) PHASES >
      • Nucleosil NO²
    • HPLC IEC (Si) PHASES >
      • Nucleosil SB
      • Partisil SAX
      • Zorbax SAX
      • Sphere-Image 80 SAX
      • Nucleosil SA
      • Partisil SCX
      • Zorbax SCX
      • Sphere-Image 80 SCX
      • PolyEncap WCX
      • IonEx CAT-S und CAT-125
    • HPLC Polymer PHASES >
      • PRP-1
    • HPLC IEC (P) PHASES >
      • PRP-X100
      • PRP-X110 und PRP-X110S
      • RCX-10
      • RCX-30
      • Eurokat
      • CarbEx II
      • PRP-X200
      • HC-40
      • HC-75
      • PRP-X300
    • Order Information PHASES
    • How to choose the right Phase?
  • HPLC LC ACCESSORIES
    • LC-Accessory Kits
    • Nuts, Ferrules, Unions aso.
    • Capillary Tube and Tubings
    • Tools
    • Filter
    • Syringes, Syringes for Autosamplers
    • Backpressures Regulators
    • Valves
  • POPLC
    • POPLink Columns
    • POPLC Basic Kit
    • POPLC Expert Kit
    • POPLC Optimizer Software
    • POPLC Spare Parts
  • SOLVENTS
  • VIALS/CAPS
    • Sample Preparation with Filter Vials >
      • PTFE Filter Vials
      • Nylon Filter Vials
      • PVDF Filter Vials
      • PES Filter Vials
      • Vorteile Filter Vials
      • Funktionsweise Filter Vial
      • Muster anfordern
    • Crimp Neck Vials and Micro-Vials ND8
    • Screw Neck Vials and Micro-Vials ND8
    • Short Thread Vials & Caps ND9
    • Crimp Neck Vials & Caps ND11
    • Snap Ring Vials & Caps ND11
    • Kunststoff Mikroflaschen
    • Flachbodenglaeser
    • Headspace ND20 (ND18) Probenflaeschchen
    • Technische Informationen Vials Caps
    • AutosamplerCompatibility Chart
    • Crimping Tools
  • DOSING PUMPS
    • HPLC Pump 3350 (Dosing Pump)
    • 3351 HPD Pump
    • Spare Parts
    • Software Download Dosing Pump

COLUMN OVEN / COLUMN THERMOSTAT VARIOTHERM 4110

For UHPLC / UPLC / HPLC / LC - COLUMN SWITCH / COLUMN SELECTION - FROM 5 to 90° C


COLUMNOVEN 4110
BISCHOFF VARIOTHERM 4110

- 5 – 90°C
- Temperature gradient
programming
- Excellent temperature
stability
- Integrated solvent pre-heater

- Vapour sensor
- Automated column selection

Almost every parameter defining a chromatographic separation is temperature dependent. Suffice it to say that temperature control provides an indispensable tool to optimize your HPLC or UHPLC assay. As you will easily recognize, retention times will be more constant with constant temperature, but varying the temperature can also be a great help to tune selectivity, improve peak shape and reduce analysis time. Plus, high temperatures reduce column back pressure significantly, allowing higher solvent flow rates, narrower columns or smaller particles. Clearly, such benefits will only come true if the temperature itself is stable and precise, and without temperature gradients in the oven or the column. And this is exactly what we had in mind when we designed the VARIOTHERM with its forced air oven, excellent temperature control and integrated solvent pre-heater.

Picture
Automated column selection
Select up to 6 different columns via
the keyboard or the PC! This feature
comes as an option and will be a
great help for method development
or if you want to run multiple assays
on a single system. UHPLC valve
available!

Reduce acetonitrile use!
Higher column temperatures allow lower acetonitrile content in the
mobile phase for the same separation or may even allow the use of
methanol instead. An easy way to save on acetonitrile!

Specifications

Parameter

value

conditions

Temperature range

5°C - 90°C, with 1°C increments

5°C - 75°C, with 1°C increments,

if optional Column Selection Valve

is installed

Ambient temperature and humidity influence the lower temperature limit of the VARIOTHERM Typically, a ΔT of 18°C is feasible.

Temperature accuracy

Better than 0.1°C

Measured at 30°C in the centre of the oven compartment

Temperature stability

Better than 0.1°C

Measured at 30°C in the centre of the oven compartment

Temperature reproducibility

Better than 0.1°C

In the centre of the oven compartment

Temperature gradient

Better than 0.2°C

Measured in the column area

Temperature change

Up: 10°C/min from 40° to 60°C

Down: 2°C/min from 60°C to 40°C

Time programmable temperature

change

Time base: 9hr59 total time with

1-minute increments

Maximum 10 programmable steps

Programmable temperature ramp

Up: 0.1 – 5.0°C/min

Down: 0.1 – 1.5°C/min (75°C to

25°C)

It is possible to program a ramp

up to 9.9°C/min; however, only

the ramp ranges specified can be

guaranteed for the actual temperature

ramp.

Dimensions (H x W x D)

600 x 170 x 345 mm (h x w x d)

Weight

16 kg

Working Environment

5 - 40°C; 30 - 80% RH

Power Requirements

115/230 VAC +15/-22%,; 50/60 Hz

Power consumption

454 VAmax

Column selection Valve

1-to-6 port high pressure solvent selection valve:

HPLC version standard

UHPLC 15,000 PSI version optional

Control

Keyboard

All functionality can be accessed and read trough the

integrated keyboard with display

Outputs:

Temperature or vapor alarm (relay + buzzer)

Relay contacts: Vmax = 28 Vdc/Vac, Lmax = 0.25A

Oven ready (relay), will be activated if the actual tempe- Lmax = 0.25A

rature is within 0.5°C of the set point temperature.

Inputs:

Start temperature program (TTL)

TTL inputs are active low and must be low for at least 1 second.

Emergency shut-down (TTL)

PC interface

RS 232 is standard.

USB or Ethernet possible on request.

A MultiLink output connector

allows linking of RS 232 communication

to other instruments

Firmware updates can be uploaded

via RS 232

SparkLink 4.0 software allows control

of main VARIOTHERM functions

from a PC.


VARIOTHERM COOL
P/N 4110 0000
VARIOTHERM COOL with COLUMN SELECTION
P/N 4110 0020

VARIOTHERM without COOL
P/N 4110 0030
VARIOTHERM without COOL with COLUMN SELECTION
P/N 4110 0040

More Information

Applications
Exhibitions
Download
Newsletter
History
Distributors
Career
Payment Terms

Terms & Conditions​
Privacy / GDPR
Imprint
Contact

Picture
Picture

Hotline: +49-7152-6064-0